Diagnostic accuracy of EUS-guided fine-needle biopsy sampling by macroscopic on-site evaluation: a systematic review and meta-analysis

Babu P. Mohan, Deepak Madhu, Nitin Reddy, Beatriz Sordi Chara, Shahab R. Khan, Gauri Garg, Lena L. Kassab, Arun Kumar Muthusamy, Achintya Singh, Saurabh Chandan, Antonio Facciorusso, Benedetto Mangiavillano, Alessandro Repici, Douglas G. Adler

Research output: Contribution to journalReview articlepeer-review

2 Scopus citations

Abstract

Background and Aims: Assessment of EUS-guided fine-needle tissue acquisition by macroscopic on-site evaluation (MOSE) is gathering attention. Studies report good diagnostic parameters with MOSE; however, the overall data are limited. We conducted this systematic review and meta-analysis to report on the pooled diagnostic assessment parameters of EUS-guided tissue acquisition by MOSE using fine-needle biopsy sampling (FNB). Methods: Multiple databases were searched (from inception to December 2021), and studies that reported on the diagnostic assessment of EUS-guided tissue acquisition by MOSE were selected. Pooled diagnostic accuracy, sensitivity, specificity, and positive and negative predictive values were calculated by standard meta-analysis methods following the random-effects model. Heterogeneity was assessed by I2 statistics. Results: Fourteen studies were included in the analysis, and 1508 lesions were biopsy sampled in 1489 patients undergoing EUS-guided tissue acquisition. MOSE definition included a visible core of tissue with opacity and “wormlike” features of adequate size and length (≥4 mm). The pooled accuracy of FNA and/or FNB specimens in yielding a pathologic diagnosis by MOSE was 91.3% (95% confidence interval [CI], 88.6-93.3; I2 = 66%), pooled sensitivity was 91.5% (95% CI, 88.6-93.6; I2 = 66%), pooled specificity was 98.9% (95% CI, 96.6-99.7; I2 = 80%), pooled positive predictive value was 98.8% (95% CI, 97.4-99.5; I2 = 33%), and pooled negative predictive value was 55.5% (95% CI, 46.9-63.9; I2 = 95%). Subgroup analyses by newer-generation FNB needles demonstrated similar pooled rates, with minimal adverse events (2.5%; 95% CI, 1.5-3.9; I2 = 21%). Conclusions: Excellent pooled diagnostic accuracy parameters were demonstrated in EUS-guided tissue acquisition by FNB using the MOSE method.

Original languageEnglish (US)
Pages (from-to)909-917.e11
JournalGastrointestinal Endoscopy
Volume96
Issue number6
DOIs
StatePublished - Dec 2022

All Science Journal Classification (ASJC) codes

  • Radiology Nuclear Medicine and imaging
  • Gastroenterology

Fingerprint